<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>AUT Journal of Mechanical Engineering</JournalTitle>
				<Issn>2588-2937</Issn>
				<Volume>9</Volume>
				<Issue>2</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>04</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Numerical Simulation of the Impact of Smoke Management Scenarios on Visibility of a Car Park</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>113</FirstPage>
			<LastPage>122</LastPage>
			<ELocationID EIdType="pii">5639</ELocationID>
			
<ELocationID EIdType="doi">10.22060/ajme.2025.23512.6140</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Ghodrat</FirstName>
					<LastName>Ghassabi</LastName>
<Affiliation>Department of Mechanical Engineering, Faculty of Engineering, Bozorgmehr University of Qenat, Qaen, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mahmood</FirstName>
					<LastName>Moghaddam</LastName>
<Affiliation>Arman Tahviye Sanabad Company, Mashhad, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Seyed Sajad</FirstName>
					<LastName>Noorbakhsh</LastName>
<Affiliation>Department of Mechanical Engineering, Faculty of Engineering, Bozorgmehr University of Qenat, Qaen, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Frahad</FirstName>
					<LastName>Yeganeh</LastName>
<Affiliation>Department of Mechanical Engineering, Faculty of Engineering, Bozorgmehr University of Qenat, Qaen, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Mahmood</FirstName>
					<LastName>Moghddam</LastName>
<Affiliation>Arman Tahviye Sanabad Company, Mashhad, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>09</Month>
					<Day>06</Day>
				</PubDate>
			</History>
		<Abstract>The mechanical ventilation smoke management system involves the use of supply fans, jet fans, and exhaust fans, which are activated at different times after a fire is extinguished. This paper numerically investigates the effect of the priority and delay of smoke management systems on smoke distribution and visibility in a car park after a fire, using Fire Dynamic Simulation Code 6.7.6. The flow rates of the exhaust fan, supply fan, and jet fan are 1.9 m³/s, 1.43 m³/s, and 1.67 m³/s, respectively. The fire, located near the supply fans, is modeled as a rectangle with dimensions of 2.0 × 0.8 m² and a power of 1.6 MW, lasting for one minute from ignition to extinguishment. Polyurethane is assumed as a flammable material. The priority and delay of the smoke management systems are evaluated through four scenarios over a period of 420 seconds. The results show that visibility reaches acceptable levels in all scenarios at all locations after 420 seconds. Additionally, the results indicate that the visibility of the upper half is highest for scenario a, at around 15 m. However, the visibility of the lower half is highest for scenario d, ranging between 20 and 30 m. It can be concluded that delaying the activation of smoke management systems is an effective strategy for facilitating smoke removal and fresh air intake.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Fire dynamic simulation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Fire</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Supply Fan</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Jet Fan</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Exhaust Fan</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ajme.aut.ac.ir/article_5639_f4f0edb08c97567ce6b0475a63bf7000.pdf</ArchiveCopySource>
</Article>
</ArticleSet>