<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Amirkabir University of Technology</PublisherName>
				<JournalTitle>AUT Journal of Mechanical Engineering</JournalTitle>
				<Issn>2588-2937</Issn>
				<Volume>7</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2023</Year>
					<Month>03</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>An investigation of pool boiling under alternating magnetic field and steady-state conditions</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>3</FirstPage>
			<LastPage>18</LastPage>
			<ELocationID EIdType="pii">4982</ELocationID>
			
<ELocationID EIdType="doi">10.22060/ajme.2022.21605.6041</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Abutaleb</FirstName>
					<LastName>Ramezani</LastName>
<Affiliation>Department of Mechanical Engineering, Yazd University, Yazd, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Ahmadreza</FirstName>
					<LastName>Faghih Khorasani</LastName>
<Affiliation>Department of Mechanical Engineering, Yazd University, Yazd, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Ahmadreza</FirstName>
					<LastName>Ayoobi</LastName>
<Affiliation>Department of Aerospace Engineering, Shahid Sattari Aeronautical University of Science and Technology, Tehran, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2022</Year>
					<Month>07</Month>
					<Day>17</Day>
				</PubDate>
			</History>
		    <Abstract>Applying an alternating magnetic field around the pool boiling region has various effects on the pool boiling&#039;s major characteristics. Steady-state pool boiling experiments were performed with deionized water under atmospheric pressure and the application of an alternating magnetic field. A nickel-chrome wire with a diameter of 0.1 mm was used as a heater. Two Helmholtz coils were used to generate the magnetic field.  The effects of applying this field with intensities of 5.8, 8.9, and 13.3 mT on pool boiling parameters were investigated in experiments and compared to the state without a magnetic field. The results show that, in general, the application of a magnetic field shortens the pool boiling process and delays the start of the nucleate boiling regime. The critical heat flux did not vary significantly when alternating magnetic fields were used. In comparison to no magnetic field application, this parameter decreased by 1.38%, 2.31%, and 3.33% at magnetic field intensities of 5.8, 8.9, and 13.3 mT. But the boiling heat transfer coefficient has increased to a maximum of 47% at the critical heat flux point. The Lorentz force acting on water molecules reduced the number of bubbles surrounding the wire heater, allowing the heat produced to be transferred to the surrounding liquid more quickly. As a result, the heat transfer coefficient increased with increasing magnetic field strength.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Pool boiling</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">alternating magnetic field</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Critical heat flux</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">heat transfer coefficient</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Lorentz force</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://ajme.aut.ac.ir/article_4982_8e0384779e58ce2af40eb365b318cc32.pdf</ArchiveCopySource>